Κλίβανοι επώασης διοξειδίου του άνθρακα CO2 ICOmed 

Classified as class IIa medical device. Equipment of basic model:

  • Temperature range from + 20 °C (however, min. 8 °C above ambient temperature) up to + 50 °C.
  • Spatial temperature deviation < ± 0.3 °C at 37 °C.
  • Temperature fluctuations with time acc. to DIN 12 880: 2007-05 ± 0.1 °C.
  • Working chamber stainless steel 1.4301 (ASTM 304) deep-drawn.
  • Housing textured stainless steel, rear zinc-plated steel.
  • Inner glass door and outer heated stainless steel door.
  • Mains supply 230 V (± 10 %), 50 / 60 Hz.
  • 2 perforated stainless steel shelves come with size 108, 3 perforated stainless steel shelves with sizes 153 and 246.
  • Acc. to DIN 12 880: 2007-05, with CE-mark.
  • Adaptive, fuzzy-supported multifunctional digital PID-microprocessor controller.
  • Integrated fault diagnostic system for temperature, CO2 as well as humidity limit control.
  • 2 Pt100 sensors DIN class A in 4-wire-circuit monitoring each other and taking over the performance at the same temperature value.
  • CO2- supply via sterile filter.
  • Digital electronic CO2 control with automatic zeroing (infrared measuring system), ranging from 0 to 10 %, setting accuracy 0.1 %, barometric pressure compensation.
  • Interruption of CO2-supply upon door opening.
  • Integrated humidity limit control (88 to 97 %) with digital display of relative humidity, setting accuracy 1 %.
  • Digital real-time / weekly programme timer with day group function, precise minute setting.
  • Digital display of all parameters such as temperature, weekday, time, CO2, humidity and set-up values. Language to be chosen via set-up.
  • Resolution of setpoint and actual values: 0.1 °C.
  • Chip-card as STERICard to sterilise the working chamber, fixed cycle (4 h / 160 °C) without removing any sensors or mountings.
  • Works calibration certificate at 37 °C included.

Multiple overtemperature protection:

  • With audible and visual alarm on over- / under-temperature, over-CO2 and empty gas cylinder, open door, under-humidity and empty water tank (with optional humidity module), open door and empty gas cylinder.
  • Independently working, digital electronic overtemperature controller TWW, protection class 3.1.
  • Additionally integrated Automatic Safety Function 'ASF' for over- and undertemperature automatically following the setpoint value at a freely selectable tolerance range.
  • Mechanical temperature limiter TB protection class 1 to switch off heating at about 10 °C above max. oven temperature.

Model

External Dimensions

Internal

Dimensions

Capacity

Weight

ICO 108med

719 x 551 x 750

560 x 400 x 480                                           

107

70

ICO 156med

719 x 591 x 1070

480 x 500 x 640

156

80

ICO 240med

820 x 750 x 950

640 x 600 x 640

241

110

Εγγύηση επιστροφής χρημάτων

Αντιμετωπίσατε πρόβλημα με κάποιο προϊόν μας ή απλά επιθυμείτε την επιστροφή του; Μπορείτε να το επιστρέψετε εντός 14 ημερών από τη παραλαβή του προς αντικατάσταση ή επιστροφή χρημάτων.

Περισσότερα ›

Έκδοση Προσφοράς

Αιτηθείτε επίσημη προσφορά για τα προϊόντα που έχετε συγκεντρώσει στο καλάθι με ένα κλικ!

Περισσότερα ›

Δωρεάν Αποστολή

Σε όλη την Ελλάδα από 50€ και άνω!

Περισσότερα ›

Από το 1947

Πάνω από 70 χρόνια τώρα δραστηριοποιούμαστε στο χώρο της υγείας, με προϊόντα και υπηρεσίες υψηλής ποιότητας, από τους μεγαλύτερους εγχώριους και διεθνείς οίκους προϊόντων υγείας!

Περισσότερα για εμάς ›